| title | MSSQLSERVER_17132 | |
|---|---|---|
| description | The SQL Server computer was unable to process the client login packet. See an explanation of the error and possible resolutions. | |
| author | MashaMSFT | |
| ms.author | mathoma | |
| ms.date | 04/04/2017 | |
| ms.service | sql | |
| ms.subservice | supportability | |
| ms.topic | reference | |
| helpviewer_keywords |
|
[!INCLUDE SQL Server]
| Attribute | Value |
|---|---|
| Product Name | SQL Server |
| Event ID | 17132 |
| Event Source | MSSQLSERVER |
| Component | SQLEngine |
| Symbolic Name | INIT_NODESSPACE |
| Message Text | Server startup failed due to insufficient memory for descriptor. Reduce non-essential memory load or increase system memory. |
Failed to allocate enough memory to store server internal descriptor.
Add more memory to the machine. Generic memory troubleshooting steps may be useful.